Mouse Osteopontin/OPN ELISA Kit检测试剂盒(一步法)
| 规格 | 96 Test |
|---|---|
| 灵敏度 | 0.18 ng/ml (10 μl) |
| 标准曲线范围 | 0.69~500 ng/ml |
| 标准曲线梯度 | 7点/3倍 |
| 孵育次数 | 2 |
| 可检测样本 | 血清,血浆 |
| 加样体积 | 10 μl |
| 类型 | 即用型 |
| 操作时长 | 60min |
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0036 | 0.0035 | 0.0035 | |
| 0.69 | 0.0082 | 0.0078 | 0.0080 | 0.0045 |
| 2.06 | 0.0231 | 0.0227 | 0.0229 | 0.0194 |
| 6.17 | 0.0776 | 0.0765 | 0.0771 | 0.0736 |
| 18.52 | 0.2525 | 0.2577 | 0.2551 | 0.2516 |
| 55.56 | 0.7773 | 0.8046 | 0.7910 | 0.7875 |
| 166.67 | 2.0170 | 2.0230 | 2.0200 | 2.0165 |
| 500.00 | 3.5410 | 3.5850 | 3.5630 | 3.5595 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(ng/ml) | 13.8 | 59.2 | 186.5 | 10.6 | 51.2 | 175.9 |
| Standard Deviation | 0.3 | 2.3 | 7.3 | 0.4 | 1.7 | 7.6 |
| Coefficient of Variation(%) | 2.5 | 3.9 | 3.9 | 3.8 | 3.4 | 4.3 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 22 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康小鼠血清加入3个不同浓度水平的小鼠Osteopontin/OPN,未加入小鼠Osteopontin/OPN的血清作为本底,计算回收率。
回收率的范围从85%至112%,平均回收率为99%。
样本值
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 46.96-265.49 | 100 | 117.02 |
应用本试剂盒,检测 30 只健康小鼠的血清样本,用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: Osteopontin/OPN
骨桥蛋白 (OPN),也称为骨唾液蛋白 (BSP),是一种分泌型 SIBLING 家族蛋白,可通过 O- 和 N-糖基化、硫酸化、磷酸化和谷氨酸转氨酰化进行可变修饰。OPN广泛表达,在矿化组织中表现突出。它抑制骨矿化和肾结石形成,促进炎症、细胞粘附和迁移。在炎症、肥胖、动脉粥样硬化、癌症和组织损伤期间,其表达被上调,并有助于这些疾病的病理生理学。OPN 的中心区域包含多个整合素的 RGD 和非 RGD 结合位点。与RGD基序相邻的是序列SLAIGLR(人中的SVVYGLR),它作为其他整合素的隐秘结合位点:它在全长OPN中被掩盖,但在OPN裂解后被肿瘤和组织损伤部位的多种蛋白酶切割。