Mammalian INHBE ELISA Kit检测试剂盒(一步法)
| 规格 | 96 Test |
|---|---|
| 灵敏度 | 0.06 ng/ml (10 μl) |
| 标准曲线范围 | 3.91~250 ng/ml |
| 标准曲线梯度 | 7点 |
| 孵育次数 | 2 |
| 可检测样本 | 血清,血浆 |
| 加样体积 | 10 μl |
| 类型 | 完全即用型 |
| 操作时长 | 60 min |
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0073 | 0.0065 | 0.0069 | |
| 3.91 | 0.0656 | 0.0629 | 0.0643 | 0.0574 |
| 7.81 | 0.1209 | 0.1289 | 0.1249 | 0.1180 |
| 15.63 | 0.2501 | 0.2472 | 0.2487 | 0.2418 |
| 31.25 | 0.5334 | 0.4981 | 0.5158 | 0.5089 |
| 62.50 | 1.0980 | 1.0110 | 1.0545 | 1.0476 |
| 125.00 | 2.0750 | 1.8970 | 1.9860 | 1.9791 |
| 250.00 | 3.2990 | 3.0870 | 3.1930 | 3.1861 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(ng/ml) | 3.4 | 15.1 | 45.8 | 4.2 | 20.0 | 53.8 |
| Standard Deviation | 0.1 | 0.6 | 2.3 | 0.2 | 0.6 | 1.3 |
| Coefficient of Variation(%) | 2.6 | 3.7 | 4.9 | 4.7 | 3.2 | 2.4 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的哺乳动物 INHBE,未加哺乳动物 INHBE 的血清作为本底,计算回收率。回收率的范围从 80 % 至 119 %,平均回收率为 96 %。
样本值
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Human Serum | 30 | 3.22-282.54 | 100 | 30.90 |
| Mouse Serum | 30 | 6.54-28.08 | 100 | 13.48 |
| Rat Serum | 30 | 3.39-149.33 | 100 | 31.78 |
| Monkey Serum | 2 | 9.74-10.17 | 100 | 9.95 |
应用本试剂盒,检测健康哺乳动物的血清样本。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: INHBE
抑制βE(INHBE)是转化生长因子β(TGF-beta)细胞因子超家族的一员,分子量约为40千道尔顿。INHBE在调控多种生理过程中发挥关键作用,包括细胞生长、分化和代谢。它是活性素信号通路的关键组成部分,在那里与其他β亚基二聚,形成参与内分泌调控的生物活性配体。INHBE主要在肝脏和生殖组织中表达,并被认为与代谢稳态有关,特别是在能量消耗和葡萄糖代谢方面。INHBE表达失调与肥胖、胰岛素抵抗和肝病等病理生理状况有关。此外,INHBE因其在某些癌症中的肿瘤抑制作用而受到关注,显示其作为细胞增殖和凋亡调控因子的潜力。其特异性及代谢和致癌途径的参与使INHBE成为有前景的生物标志物,并成为治疗策略的潜在靶点。