Human PARK7/DJ-1 ELISA Kit检测试剂盒(一步法)
| 规格 | 96 Test |
|---|---|
| 灵敏度 | 5.36 ng/ml (50 μl);9.83 ng/ml (10 μl); |
| 标准曲线范围 | 15.63~1000 ng/ml |
| 标准曲线梯度 | 7点 |
| 孵育次数 | 2 |
| 可检测样本 | 血清,血浆 |
| 加样体积 | 50 μl/10 μl |
| 类型 | 即用型 |
| 操作时长 | 60min |
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0645 | 0.0580 | 0.0613 | |
| 15.63 | 0.0995 | 0.0885 | 0.0940 | 0.0328 |
| 31.25 | 0.1349 | 0.1260 | 0.1305 | 0.0692 |
| 62.50 | 0.2386 | 0.2181 | 0.2284 | 0.1671 |
| 125.00 | 0.4859 | 0.4609 | 0.4734 | 0.4122 |
| 250.00 | 1.0050 | 0.9409 | 0.9730 | 0.9117 |
| 500.00 | 2.0200 | 1.8750 | 1.9475 | 1.8863 |
| 1000.00 | 3.6210 | 3.4590 | 3.5400 | 3.4788 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(ng/ml) | 25.6 | 98.7 | 300.9 | 30.2 | 89.7 | 298.6 |
| Standard Deviation | 7.1 | 15.4 | 57.9 | 8.2 | 15.5 | 69.4 |
| Coefficient of Variation(%) | 3.6 | 6.4 | 5.2 | 3.7 | 5.8 | 4.3 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 22 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入3个不同浓度水平的人PARK7/DJ-1,未加入人PARK7/DJ-1的血清作为本底,计算回收率。
回收率的范围从70%至105%,平均回收率为85%。
样本值
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 51.93-342.23 | 100 | 153.14 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: PARK7/DJ-1
Park7/DJ-1 是多个被认为是导致常染色体隐性早发性帕金森病的基因之一。它还作为雄激素受体依赖转录的正向调节剂,同时作为氧化还原敏感的伴护蛋白,作为氧化应激的传感器,显然还能保护神经元免受氧化应激和细胞死亡的侵害。