Human Oxytocin-neurophysin 1/OXT ELISA Kit检测试剂盒
规格 | 96 Test |
---|---|
灵敏度 | 1.02 pg/ml (50 μl);4.22 pg/ml (10 μl) |
标准曲线范围 | 40.96~10000 pg/ml |
标准曲线梯度 | 7点 |
孵育次数 | 2 |
加样体积 | 50 μl/10 μl |
类型 | 完全即用型 |
操作时长 | 120min |

pg/ml | O.D. | Average | Corrected | |
---|---|---|---|---|
0.00 | 0.0068 | 0.0081 | 0.0075 | |
40.96 | 0.0280 | 0.0282 | 0.0281 | 0.0207 |
102.40 | 0.0630 | 0.0590 | 0.0610 | 0.0536 |
256.00 | 0.1461 | 0.1605 | 0.1533 | 0.1459 |
640.00 | 0.4384 | 0.4124 | 0.4254 | 0.4180 |
1600.00 | 1.1440 | 1.1410 | 1.1425 | 1.1351 |
4000.00 | 2.9610 | 2.8740 | 2.9175 | 2.9101 |
10000.00 | 4.0079 | 4.1190 | 4.0635 | 4.0560 |
精度
Intra-assay Precision | Inter-assay Precision | |||||
Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
22 | 22 | 22 | 6 | 6 | 6 | |
Average(pg/ml) | 218.3 | 1133.2 | 3538.1 | 221.8 | 1122.4 | 3350.1 |
Standard Deviation | 6.8 | 40.5 | 130.7 | 6.3 | 60.8 | 184.5 |
Coefficient of Variation(%) | 3.1 | 3.6 | 3.7 | 2.8 | 5.4 | 5.5 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人 Oxytocin-neurophysin 1/OXT,未加人 Oxytocin-neurophysin 1/OXT 的血清作为本底,计算回收率。回收率的范围从 95 % 至 119 %,平均回收率为 103%。
样本值
Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
---|---|---|---|---|
Serum | 30 | 23.53-1127.81 | 100 | 175.25 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
产品数据表
背景: Oxytocin-neurophysin 1/OXT
催产素是一种垂体后叶激素,在下丘脑中与其载体蛋白神经physin I一起合成为无活性的前体。它与神经physin一起包装成神经分泌囊泡,并轴突运输到神经垂体的神经末梢, 它被储存或分泌到血液中。